USER MANUAL
CLASSIC / air purifier
CLASSIC CLASSIC
TABLE OF CONTENTS
SAFETY INSTRUCTIONS 2
PRODUCT BENEFITS 3
KNOWING YOUR AIR DOCTOR® AIR PURIFIER 4
Main Parts 4
PROPER USAGE 5
OPERATING YOUR AIR DOCTOR® AIR PURIFIER 6
Control Panel 6
Air Quality Monitor 7
MAINTENANCE 9
Maintaining the AirDoctor® Air Purifier 9
TROUBLE-SHOOTING 9
CUSTOMER SERVICE CONTACT INFORMATION 11
ONE-YEAR LIMITED WARRANTY 11
ARBITRATION AGREEMENT 12
THANK YOU
Congratulations on purchasing the
AirDoctor® Classic professional air
purifier and your commitment to
controlling the quality of your indoor air.
With the AirDoctor® Classic professional
air purifier, we provide UltraHEPA
filtration to purify the air and remove
allergens. In addition, AirDoctor® Classic
is equipped with an activated carbon
filter to remove odor and VOCs. Get
ready to experience cleaner air!
PLEASE NOTE: It is crucial that you
read and follow all the instructions
and safety warnings in this manual
for optimal performance of your air
purifier and your health
and safety.
CLASSIC CLASSIC
32
SAFETY INSTRUCTIONS
WARNING: RISK OF ELECTRIC SHOCK
Safety precautions should always be used when operating this or any electrical appliance.
Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the
warnings below.
Use this product only as described in this AirDoctor® professional air purifier owner’s guide.
To reduce the risk of electric shock, do not attempt to service the product in any way other than
in the manner described in the “Maintenance” section of this guide.
Read all instructions before operating the AirDoctor® professional air purifier.
This product operates at 120V AC, 60Hz only.
Do not run the power cord under carpets or cover with throw rugs.
Do not operate the product in a greasy environment such as in the kitchen. This product is
not intended to filter oil or grease from air.
Do not use the AirDoctor® professional air purifier in bathrooms, near sinks or other wet &
humid environments, near fireplaces or in areas where flammable or combustible vapors or
products may exist.
Always unplug the power cord from the electrical outlet when the purifier is not in use,
before cleaning, inserting or removing parts or before moving to another location.
Never run the air purifier unless it is fully assembled.
To reduce the risk of electric shock, this product has a polarized plug (one blade is wider
than the other). This plug will fit into a polarized outlet only one way. If the plug does not fit
into the outlet, contact qualified service personnel to install the proper outlet. Do not alter
the plug in any way.
Always turn off all controls before unplugging the AirDoctor® professional air purifier
from outlet.
Attempting to service the AirDoctor® professional air purifier in any way not described in this
owner’s guide will void the warranty and could cause serious personal injury to the user and/
or result in considerable damage to the unit.
Do not place the cord near a heated surface.
Never operate the AirDoctor® professional air purifier if the plug or cord is damaged or
appears damaged. Only qualified service personnel should replace a damaged power cord.
Never use the power cord to pick up, carry, drag, pull or lift the AirDoctor® professional air
purifier. Do not pull the cord against or around sharp corners and edges. This could result in
injury to the user or damage to the cord.
Always remove the plug from its power outlet by holding onto the plug itself and pulling
gently. Never pull on the cord itself to unplug it from its power outlet.
Use care when operating the AirDoctor® professional air purifier by keeping all foreign
objects, fingers and other body parts, hair, loose clothing and jewelry away from openings.
Never touch the AirDoctor® professional air purifier or its plug when your hands are wet.
The AirDoctor® professional air purifier is an electrical appliance. Adult supervision is
required when operating around children.
PRODUCT BENEFITS
THE REVOLUTIONARY AIR DOCTOR® PROFESSIONAL AIR PURIFIER
CLEANS AIR WITH ULTRAHEPA™ FILTRATION.
The AirDoctor® professional air purifier boasts many great features:
UltraHEPA™ filter removes microscopic particles from the air.
High quality carbon filter removes VOCs (Volatile Organic Compounds) and controls odors.
Effectively removes smoke, pollen, dust, animal dander, dust mites from the air.
Powerful and quiet fan has 4 speed settings so you can select the desired cleaning level.
Air Quality Monitor shows current air quality.
Auto mode automatically adjusts fan speed depending on air quality.
A 24 hour timer to set the time of operation, from 1 hour up to 24 hours.
Built-in ionizer revitalizes air.
Night mode dims the control panel light when you sleep.
Clean filter indicator light.
Low power consumption-energy efficient, Energy Star approved.
CLASSIC CLASSIC
54
PROPER USAGE
Please note: make sure the UltraHEPA™ & Carbon/Gas Trap/VOC filters are properly installed
before use.
1. Keep both sides of the unit more than 1 foot away from a wall.
2. Do not blow air from a fan or air conditioner directly into the air purifier.
3. Do not place the unit where the air inlet or outlet grill could come in contact with curtains
or drapery.
4. Place the unit close to the source of air pollution to improve indoor air quality effectively.
KNOWING THE AIR DOCTOR
®
CLASSIC AIR PURIFIER
MAIN PARTS
1. Front Cover
2. Pre-Filter (attached to the VOC filter)
3. Carbon/Gas Trap/VOC Filter
4. UltraHEPA™ Filter
5. Air-Outlet
6. Touch Control Panel
7. Air Quality Sensor Cover
8. Air Quality Sensor
9. Air Quality Monitor: The display will change color depending on air quality.
3 4
1
2
6) Touch Control
Panel
9) Air Quality
Monitor
7) Air
Quality
Sensor
Cover
1) Front Cover
4) UltraHEPA™
Filter
8) Air
Quality
Sensor
3)
Carbon/
Gas Trap/
VOC
Filter
2) Pre-
Filter
5) Air
Outlet
CLASSIC CLASSIC
76
OPERATING THE AIR DOCTOR
®
CLASSIC AIR PURIFIER
OPERATING THE AIR DOCTOR
®
CLASSIC AIR PURIFIER
Electrical Ratings
120 volt / 60 Hz
Power consumption / 95 watts
12 month UltraHEPA™ filter
6 month Carbon filter
Model AD3000
Replacement Filters
UltraHEPA™ filter / ADF3001
Carbon filter / ADF3002
Pre-filter / ADF3003
Before first use, remove filters and remove plastic bag from filters, then reinstall filters.
Then reinstall front cover.
Plug the unit into an electrical outlet. The unit will be ready to run. Read the following directions
to select desired settings.
AIR QUALITY MONITOR
Air Monitor
The Air Doctor® comes with an Air Quality Monitor that continuously monitors the quality
of the air in the room. The LED light located on the front will light up according to the air
quality. The Air Quality Monitor is able to show 3 air quality levels.
BLUE = Good air quality / ORANGE = Fair air quality / RED = Poor air quality
You can choose to set the Air Doctor® to “Auto. This will enable the Air Doctor® to adjust the
Fan speed according to the Air Quality. In Auto mode, the fan speed will be adjusted
as follows:
Good Air Quality = Low fan speed
Fair Air Quality = Medium fan speed
Poor Air Quality = High and Boost fan speed
CONTROL PANEL
1. Power Control
As soon as you press the power button , the Air Doctor® will start in the Auto mode. As
soon as the auto program has been activated it will start up in the high-speed mode, the
sensor will start to detect the amount of particulate in the air. As the particles are detected,
the Air Doctor® will select the purification speed (fan speed) that is appropriate to the
particulate contamination in the room.
In most cases we recommend that you leave the Air Doctor® in the Auto mode, for other
purification modes, see the next page.
2. Fan Speed Control
The Air Doctor® has four different fan speed settings: Low, Medium, High, and Boost. Each
mode has its own indicator light which lights up when the setting is chosen. The speed
selected determines how rapidly you want to clean the air. The “LOW” and “MEDIUM
settings are great for everyday use. The “HIGH” setting is great for areas with more airborne
contaminants (such as excessive smoke, pet dander, etc), or areas used frequently by
allergy-sufferers. The “BOOST” setting is best used for shorter bursts of time when you
want to rapidly purify the air.
3. Auto Mode
The Air Doctor® is equipped with an air sensor to monitor the quality of your air. Simply
press the Auto button to activate the air monitoring system. The monitor will test the air
quality and automatically adjust the fan speed to remove the air contaminants. The front of
the display is equipped with LED lights to notify you of the air quality. RED color is for poor,
ORANGE for fair and BLUE for good quality air.
4. Dim Mode
If the LED lights are too bright, activate the “Dim Mode” to turn off the LED lights and
the lighted display.
5. Timer Control
The Air Doctor® air purifier can be programmed to turn off after a preset amount of time.
Press the “TIME” button to program the timer. Each press will add one hour up to a total of 24
hours. Keeping the button pressed will automatically increase to 24 hours, 1 hour at a time.
6. ION Generator
Press the ION button to turn on the IONs. Press it again to turn the IONs off.
7. Clean Filter Indicator Light
The Air Doctor® Clean Filter Indicator Light will turn on each time a filter needs to be
replaced. To reset the filter indicator, press the AUTO and DIM buttons together for 3 seconds.
The CLEAN FILTER light will flash 3 times and then turn off completely, indicating the unit has
been reset.
8. 24-Hour Timer Display
To order replacement filters go to airdoctorpro.com or call 800.221.2515.
Air Quality Monitor
1 2 3 4 5 6 7 8
CLASSIC CLASSIC
98
MAINTENANCE
MAINTENANCE
Cleaning the Air Monitor
The Air Doctor® is designed with an air monitor to
track the quality of your air. Over time the monitor
can become dirty and may require cleaning. The main
symptom of a dirty air monitor is the LED display
remains frozen on one light color. In order to clean
the air monitor you must use a vacuum to clear the
monitor chamber.
1. Power off and unplug unit.
2. Locate and open the air sensor panel door
located on the side of the unit. (Fig. 1)
3. Use a vacuum cleaner hose to suction any dust
or dirt that may have accumulated inside the
monitor chamber. (Fig. 2)
The AirDoctoprofessional air purifier is almost
maintenance free! The high quality carbon/
gas trap/VOC filter lasts up to 6 months and
our UltraHEPA™ filter lasts up to 12 months,
depending on use and environment conditions.
Before replacing the UltraHEPA™ or carbon/gas
trap/VOC filter of your AirDoctor® professional
air purifier, turn off and unplug the unit from the
electrical outlet and read all safety instructions
and important warnings in this owner’s manual.
REPLACING THE ULTRAHEPA
& CARBON/GAS TRAP/VOC FILTERS
1. Make sure the unit is turned off and
unplugged. With the front of the unit facing
forward, pull the lid towards you at the upper
end as shown and remove the front cover.
2. Remove the UltraHEPA™ and carbon/gas
trap/VOC filters by lifting and pulling the tabs
on both sides of the filters.
3 . Insert new UltraHEPA™ and carbon/gas trap/
VOC filters, then insert the bottom of the
inlet grill first and then snap the upper part
of the front cover back into position.
4 . To close the front cover, first make sure the
bottom hooks are properly in place before
snapping it up to its upright and locked
position.
CLEANING THE PREFILTER
1. Make sure the unit is turned off and
unplugged. With the front of the unit facing
forward, pull the lid towards you at the upper
end as shown and remove the front cover.
2. Gently remove the reusable pre-filter from
front side of the carbon filter.
3. To clean the pre-filter, simply submerge in
warm soapy water. Gently lift and submerge
the pre-filter several times until it is clean.
4. Rinse the pre-filter with clean water and
allow it to dry completely before placing it
back onto the front side of carbon filter.
1.
4.
3.
2.
TROUBLESHOOTING
Before contacting our customer service department, please try the following solutions:
Figure 1
Figure 2
PROBLEM REASON SOLUTION
Unit won’t operate. ON/OFF button hasn’t
been pressed.
Unit is unplugged.
Press ON/OFF button.
Plug in unit.
Reduced air flow or
poor filtering.
The inlet or outlet grill
may be blocked.
The UltraHEPA™ or
carbon/gas trap/VOC filter
may be clogged.
Filters may still be in bags.
Ensure nothing is in front of
or on top of the purifier.
Check filters and replace
it if necessary.
(See instructions on pg. 8).
Remove filters from bags.
CLASSIC CLASSIC
1110
ONE-YEAR LIMITED WARRANTY
AIR DOCTOR
®
ONEYEAR LIMITED WARRANTY
Your AirDoctor® air purifier is warranted to be free from defects in materials and workmanship
for one year from the original purchase date. Should the product have a defect in materials or
workmanship, we will repair or replace it without charge to you (a shipping and processing fee
will apply). To obtain service under warranty, simply call our customer service center toll-free at
800.221.2515.
This warranty does not cover damage caused by accident, misuse or any use other than as
intended and described in this product manual, or damage resulting from failure to maintain and
clean this product as specified in this product manual. This warranty applies only to the original
purchaser of the AirDoctor®
air purifier. This warranty does not cover the filters.
AIR DOCTOR
®
VOC, HEPA AND PREFILTER
LIMITED WARRANTY
Your AirDoctor® particle filter (HEPA) and VOC (carbon) and Pre-filter is warranted to be free from
defects in material and workmanship for 30 days from the original purchase date. AirDoctor® will
replace a defective filter at no charge to you and cover any shipping charges. The limited warranty
covers normal use only.
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT, INCLUDING IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO
THE WARRANTY PERIOD, AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER
THIS PERIOD.
Some states do not allow limitations on the duration of implied warranties, so the above
limitation may not apply to you. While this warranty gives you specific legal rights, you may also
have other rights which may vary from state to state.
CONTACT INFO FOR WARRANTY SERVICE:
AirDoctor®
P.O. Box 9159 | Van Nuys, CA | 91409-8291
800.221.2515
|
airdoctorpro.com
©
2019 AirDoctor®, LLC. All Rights Reserved.
TROUBLESHOOTING
Before contacting our customer service department, please try the following solutions:
PROBLEM REASON SOLUTION
The air quality
monitor only
illuminates blue.
The air in your room
is clean.
The unit is operating
normally, no action
required
The air quality
monitor only
illuminates
yellow or red.
Either the air quality
is very poor or the air
monitor sensor has
become dirty.
Clean the air sensor with a
vacuum to restore the
accuracy of the monitor.
(See page 9 for instruction
on how to clean the sensor)
The FILTER 1 or
FILTER 2 light has
come on and won’t
turn off.
The AirDoctor is designed
to notify you when it is
time to change each filter.
These lights indicate that
one of the filters needs to
be replaced.
First, remove and replace
the filter that needs to
be changed. Second,
press and hold the
AUTO and DIM button
simultaneously to reset
the filter life tracker and
turn off notification light.
The AUTO mode
is not activating
the ION mode.
The AUTO mode is
designed to adjust the
fan speed depending
on the air quality. Other
modes must be activated
separately
The unit is operating
normally, no action
required
CLASSIC CLASSIC
1312
ARBITRATION AGREEMENT
PLEASE READ THIS AGREEMENT CAREFULLY. YOU ACCEPT THE TERMS OF THIS AGREEMENT BY
RETAINING THE PRODUCT(S) SHIPPED IN CONNECTION WITH THIS AGREEMENT (THE “PRODUCTS”)
FOR MORE THAN THIRTY (30) DAYS AFTER RECEIPT. IF YOU DO NOT AGREE TO THE TERMS OF THIS
AGREEMENT, YOU MAY RETURN THE PRODUCT TO COMPANY WITHIN THIRTY (30) DAYS OF RECEIPT
FOR A FULL REFUND.
THIS ARBITRATION AGREEMENT (“AGREEMENT”) AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY
PROVIDING THAT DISPUTES BETWEEN YOU AND THE MANUFACTURER, DISTRIBUTOR AND/OR SELLER
OF THIS PRODUCT (COLLECTIVELY, “COMPANY”), MUST BE RESOLVED THROUGH BINDING ARBITRATION
AND NOT IN COURT. IT ALSO PROVIDES THAT ANY DISPUTE CANNOT BE RESOLVED IN A CLASS ACTION
OR OTHER PROCEEDING WHERE YOU REPRESENT OTHER PERSONS OR OTHER PERSONS REPRESENT
YOU, AND THAT NO CLASS OR REPRESENTATIVE ARBITRATIONS ARE PERMITTED. PLEASE CAREFULLY
READ ALL TERMS IN THIS AGREEMENT.
1. RESOLUTION OF CLAIMS OR DISPUTES. Any claim or dispute between you and Company (or any
of Company’s subsidiaries or affiliates) arising out of or relating in any way to the Product or
this Agreement shall be resolved through final, binding arbitration. This arbitration obligation is
reciprocally binding on both you and the Company and applies regardless of whether the claim
or dispute involves a tort, fraud, misrepresentation, product liability, negligence, violation of a
statute, or any other legal theory. Both you and Company specifically acknowledge and agree that
you waive your right to bring a lawsuit based on such claims or disputes and to have such lawsuit
resolved by a judge or jury.
2. LIMITATION OF LEGAL REMEDIES. All arbitrations under this Agreement shall be conducted on
an individual (and not a class-wide) basis, and an arbitrator shall have no authority to award
class-wide relief. You acknowledge and agree that this Agreement specifically prohibits you and
the Company from commencing arbitration proceedings as a representative of others or joining
in any arbitration proceedings brought by any other person. The parties agree that no class or
representative actions of any type are permitted.
3. ARBITRATION PROCEDURES.
a. Before instituting an arbitration, if you have any dispute, we strongly encourage you to contact
the Company to try to resolve the matter by calling 800-218-3560, although you are not required to
do so.
b. The arbitration of any claim or dispute under this Agreement shall be conducted in accordance
with the expedited procedures set forth in the JAMS Comprehensive Arbitration Rules and
Procedures as those Rules exist on the date you receive the Product, including Rules 16.1 and 16.2
of those Rules. These rules and procedures are available by calling JAMS or by visiting its web
site at www.jamsadr.com. The arbitration of any claim or dispute under this Agreement shall be
conducted by an arbitrator who has at least five years of experience conducting arbitrations.
c. The arbitration of any claim or dispute under this Agreement shall be conducted in the State of
California or the location in which you received this Agreement. For claims of $10,000 or less,
you may choose whether the arbitration proceeds in person, by telephone, or based only on
submissions.
d. The Company shall pay costs for the arbitration of claims, including any JAMS Case Management
Fee and all professional fees for the arbitrator’s services. The Company shall pay the fees and
costs of its own counsel, experts and witnesses and shall not be able to recoup them from you
even if you do not prevail in the arbitration. Unless otherwise provided by law, you acknowledge
and agree that you shall pay the fees and costs of your own counsel, experts and witnesses.
4. CHOICE OF LAW. The arbitration provisions of this Agreement and any arbitration conducted
pursuant to the terms of this Agreement shall be governed by the Federal Arbitration Act (9 U.S.C.
Secs. 1-16). In this respect, the parties acknowledge that this Agreement involves a transaction
conducted in interstate commerce. Otherwise, this Agreement and the rights of the parties
hereunder shall be governed by and construed in accordance with the laws of the State of
California, exclusive of conflict or choice of law rules.
5. SEVERABILITY. If any provision of this Agreement is declared or found to be unlawful,
unenforceable or void, such provision will be ineffective only to the extent that it is found
unlawful, unenforceable or void, and the remainder of the provision and all other provisions
shall remain fully enforceable.
Cl a ss ic / MN L / US / 0 90 419R 2
airdoctorpro.com